FEREX 4.034
Digital fluxgate magnetometer for detection of ferromagnetic metals with data logging and comprehensive application software
Precise detection of geomagnetic anomalies. With the FEREX 4.034 detection of geomagnetic anomalies is as simple and precise as ever. The significantly improved signal-to-noise ratio, comprehensive application software and reduced weight facilitate detection. Up to 4 probes can be used on a probe holder. Linking a GPS system the exploration area and the tracks can be easily defined. The optional navigation system provides valuable information on the current position, deviation from the ideal track as well as the data quality already during data acquisition. Results are displayed directly on the color screen, providing initial analysis.
Product highlights
Technical information
| FEREX 4.034 | |
| Weight: | 4.1 kg complete detector incl. batteries 12.1 kg complete detector set in case |
| Dimensions: | FEREX – 1270 × 145 × 850 mm (L × W × H) Case – 989 × 415 × 157 mm (L × W × H) |
| Display: | 3.5“ LCD with adjustable back-light, sunlight readable |
| Memory: | 32 GB SD card |
| Interfaces: | 4 × analog Fluxgate Gradiometer, 1 × serial |
| Temperature range: | Operation: -37 °C to +71 °C; -99 °F to +160 °F (ambient temperature) Stock: -57 °C to +71 °C; -135 °F to +160 °F |
| Power supply: | 4 × 1.5 V alkaline batteries (LR20) or 4 × 1.2 V NiMH (HR20) |
| Battery size: | IEC LR20/HR20 – ANSI „D“ |
| Battery lifetime: | 1 probe, continuous operation > 8 hrs |
| Measuring ranges in FEREX mode: | 8 linear ranges: ±3 nT to 10,000 nT and 1 logarithmic range |
| Sampling rate | 900 Hz each channel |
| Resolution: | 24 bit ADC |
| Protection grade: | IP65 |
| NATO Stock Number: | Probe MG-10-550, 2042037, 6665-12-410-0248 |
| Probe MG-10-550 | |
| Type: | Fluxgate Gradiometer |
| Base distance: | 550 mm |
| Application area: | ±62.500 nT |
| Measuring range: | ±10.000 nT gradient ±62.500 nT absolute |
| Reference point: | 97,5 mm from end of probe rod, 4 mm outside symmetry axis |
| Declination: | ±3 nT |
| Noise: | <40 pT √ Hz @ 1 Hz |
| Cut-off frequency: | 230 Hz |
| Temperature drift: | <1 nT/K |
| Uncertainty of measurement: | <2 % ref. ±10.000 nT |
| Linearity: | <1 nT referred to maximum measuring range |
| Protection grade: | IP68, 100 m with optional sealing plug |
| External dimensions: | Diameter 39.4 mm (with protective cap), probe length 750 mm, base distance 550 mm |